Field · ASTM E1105High-rise water-penetration testing in Los Angeles
On-site E1105 spray testing of installed curtain wall to isolate infiltration paths across multiple floors.
Read the case →Browse the site, or type a term like “E1105”, “water”, or “forensic”.
No matches. Try a standard code like “E1105” or a term like “water”.
Independent testing lab · Los Angeles · Est. 1988
Independent air, water, and forensic water-intrusion testing of windows, doors, and curtain walls — in the field and in the lab, across California.
Who we are
Fenestration Testing Laboratory, Inc. (FTL) was established in 1988 and is an ISO 17025–accredited test facility offering field and laboratory testing, forensic water-leak investigation, and consulting for fenestration products and the surrounding components of a building's envelope.
Our clients include manufacturers, architects, waterproofing consultants, general contractors, installers, and building owners. As an independent third party, we've provided investigative leak-detection and water-intrusion testing across California for over 35 years.
See our capabilitiesCapabilities
On-site air-infiltration and water-penetration testing of installed windows, doors, and curtain walls.
Learn more → LABAdhesion, air leakage, water-penetration resistance, structural loading, operating force, life cycling, and missile-impact resistance — including a computer-controlled missile-impact cannon.
Learn more → FORENSICIndependent third-party forensic water-intrusion investigation and expert analysis for construction-defect claims — we find out why the building leaks.
Learn more → EQUIPWe manufacture, repair, and calibrate ASTM E1105 spray racks, field pressure kits, AAMA 501.2 spray wands, and E783 air-leakage test kits — with an annual calibration program.
Learn more →Accreditations
Independently accredited and audited — so your results stand up to manufacturers, code officials, and the courtroom alike.
Selected work
Field · ASTM E1105On-site E1105 spray testing of installed curtain wall to isolate infiltration paths across multiple floors.
Read the case →
LaboratoryComputer-controlled missile-impact cannon qualifying window systems for impact and cyclic wind-pressure performance.
Read the case →
EquipmentIn-house manufacture and calibration of ASTM E1105 spray racks and field pressure kits for testing crews.
Read the case →Request a quote
Send the standard, building type, location, and timeline — we'll come back with scope and scheduling. Prefer to talk?